{"id":null,"ids":[],"kind":"named in documents","name":"Francisco Reservoir","tied_by":"name","block":null,"release":"v0.7.1","rows_columns":["t","id","year","y","date","kind","topic","outcome","summary","tier","source","leaf","scan","addr","quote","note","title","how","g","rec","sc"],"rows":[["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:13/6",1990,1861,"1861","building","study or report",null,"Francisco Reservoir · built: Constructed","unverified","C124904960",13,"https://archive.org/details/C124904960/page/n12",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:23/4",1990,1861,"1861","building","study or report",null,"Francisco Reservoir · built: 2.5 million gallon reservoir constructed","unverified","C124904960",23,"https://archive.org/details/C124904960/page/n22",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:41/4",1990,1861,"1861","site","study or report",null,"Francisco Reservoir · built year: 1861","unverified","C124904960",41,"https://archive.org/details/C124904960/page/n40","Hyde Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124916544:20/1",1997,1974,"1974","finding","plan",null,"Map 7 [name withheld] to Reservoir Failure · other: Possible area of inundation due to reservoir failure, estimated by San Francisco Water Department","unverified","C124916544",20,"https://archive.org/details/C124916544/page/n19",null,null,null,"Community safety : proposal for adoption : an element of the Master plan of the City and County of San Francisco","n","a",0,2.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124889945:11/10",1985,1985,"","building","study or report",null,"Francisco Reservoir · other: Reservoir on north slope of Russian Hill, elevation 135 feet, still in use","unverified","C124889945",11,"https://archive.org/details/C124889945/page/n10",null,null,null,"San Francisco water & power : a history of the Municipal Water Department and Hetch Hetchy System","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:101/2",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: Formerly supplied a portion of the University Mound service area","unverified","C124904960",101,"https://archive.org/details/C124904960/page/n100",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:105/9",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: Invaluable fire reserve facility per SFFD; remote from supply source, adjacent to Marina and North Beach Districts","unverified","C124904960",105,"https://archive.org/details/C124904960/page/n104",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:109/10",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · recommendation: renovation would provide this storage","unverified","C124904960",109,"https://archive.org/details/C124904960/page/n108",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:13/5",1990,1990,"","building","study or report",null,"Francisco Reservoir · other: 2.5-million-gallon single brick-lined basin, located on Russian Hill","unverified","C124904960",13,"https://archive.org/details/C124904960/page/n12",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:133/1",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: located in the northeast corner of San Francisco on the north slope of Russian Hill","unverified","C124904960",133,"https://archive.org/details/C124904960/page/n132",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:133/2",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: underlain by shale and sandstone of the Franciscan Complex; bedrock should be mostly shale with some sandstone at the southeast corner","unverified","C124904960",133,"https://archive.org/details/C124904960/page/n132",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:133/3",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: Franciscan may be mantled with 5 to 10 feet of slope debris; elevation 125 bench cut into bedrock except along north berm toe","unverified","C124904960",133,"https://archive.org/details/C124904960/page/n132",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:137/1",1990,1990,"","building","study or report",null,"Francisco Reservoir · other: capacity approximately 2.5 million gallons","unverified","C124904960",137,"https://archive.org/details/C124904960/page/n136",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:137/2",1990,1990,"","building","study or report",null,"Francisco Reservoir · other: 410 feet long by 120 feet wide by 8 feet deep","unverified","C124904960",137,"https://archive.org/details/C124904960/page/n136",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:137/3",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: brick lining in some areas is deteriorating","unverified","C124904960",137,"https://archive.org/details/C124904960/page/n136",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:137/4",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: many older redwood posts show deterioration near the bottom and at the water line level","unverified","C124904960",137,"https://archive.org/details/C124904960/page/n136",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:137/5",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: roofing is aging and shows great signs of wear; boards cracked and loose","unverified","C124904960",137,"https://archive.org/details/C124904960/page/n136",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:137/6",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: reservoir is not in use at the present time","unverified","C124904960",137,"https://archive.org/details/C124904960/page/n136",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:137/7",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · recommendation: must be repaired before being returned to the City's distribution system","unverified","C124904960",137,"https://archive.org/details/C124904960/page/n136",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:137/8",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: available data not adequate for evaluating static and seismic stability of embankment and foundation","unverified","C124904960",137,"https://archive.org/details/C124904960/page/n136",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:137/9",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · recommendation: site-specific geotechnical study should be performed, including seismic stability evaluation of existing slopes","unverified","C124904960",137,"https://archive.org/details/C124904960/page/n136",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:139/1",1990,1990,"","site","study or report",null,"Francisco Reservoir · recommendation: bottom of the reservoir removed and replaced with a concrete slab","unverified","C124904960",139,"https://archive.org/details/C124904960/page/n138",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:139/2",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · recommendation: returned to service after remedial steps","unverified","C124904960",139,"https://archive.org/details/C124904960/page/n138",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:139/3",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: water level must be raised to between Elevation 145 and 150","unverified","C124904960",139,"https://archive.org/details/C124904960/page/n138",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:139/4",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · other: height of the berms raised ten to fifteen feet and brick lining replaced","unverified","C124904960",139,"https://archive.org/details/C124904960/page/n138",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:139/5",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · recommendation: entire deck, roofing, columns, and foundation replaced with structural system like Balboa Reservoir South Basin","unverified","C124904960",139,"https://archive.org/details/C124904960/page/n138",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:143/1",1990,1990,"","measure","study or report",null,"Francisco Reservoir · cost usd: 4,280,433","unverified","C124904960",143,"https://archive.org/details/C124904960/page/n142",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:143/2",1990,1990,"","measure","study or report",null,"Francisco Reservoir · cost usd: 558,317 contingencies (15%)","unverified","C124904960",143,"https://archive.org/details/C124904960/page/n142",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:143/3",1990,1990,"","building","study or report",null,"Francisco Reservoir · floor area sqft: 49,200 S.F.","unverified","C124904960",143,"https://archive.org/details/C124904960/page/n142",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:151/3",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: overflow elevation of 135 feet","unverified","C124904960",151,"https://archive.org/details/C124904960/page/n150",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:151/4",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: can serve most of the Marina and North Beach Districts","unverified","C124904960",151,"https://archive.org/details/C124904960/page/n150",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:151/5",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: service area could include most of the Financial District, to as high as Kearney Street","unverified","C124904960",151,"https://archive.org/details/C124904960/page/n150","Kearney Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:151/6",1990,1990,"","alternative","study or report",null,"Francisco Reservoir · alternative: raising reservoir up to an additional 40 feet to elevation 175 feet would marginally expand service area","unverified","C124904960",151,"https://archive.org/details/C124904960/page/n150",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:151/7",1990,1990,"","alternative","study or report",null,"Francisco Reservoir · rejected: hydro-pneumatic tank on the site was not considered","unverified","C124904960",151,"https://archive.org/details/C124904960/page/n150",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,-4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:175/17",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: 2.5 MG reservoir on Russian Hill with overflow elevation of 135 feet","unverified","C124904960",175,"https://archive.org/details/C124904960/page/n174",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:183/6",1990,1990,"","finding","study or report",null,"Francisco Reservoir low pressure area · finding: low pressure area located just below the Francisco Reservoir","unverified","C124904960",183,"https://archive.org/details/C124904960/page/n182",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:183/8",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · finding: reservoir volume must meet full duration of high demand to prevent draining","unverified","C124904960",183,"https://archive.org/details/C124904960/page/n182",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:185/1",1990,1990,"","alternative","study or report",null,"University Mound pressure zone - Use of existing Francisco Reservoir · alternative: Re-connection of existing 135-foot Francisco Reservoir offers minimal pressure benefit","unverified","C124904960",185,"https://archive.org/details/C124904960/page/n184","Larkin Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","m",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:185/3",1990,1990,"","alternative","study or report",null,"Francisco Reservoir enlarged and raised · alternative: Raise Francisco Reservoir to overflow elevation of 172 feet to float on University Mound system","unverified","C124904960",185,"https://archive.org/details/C124904960/page/n184",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:185/4",1990,1990,"","finding","study or report",null,"Francisco Reservoir service area · finding: Inadequate pressures in the Marina and North Beach Districts under present system characteristics","unverified","C124904960",185,"https://archive.org/details/C124904960/page/n184",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:185/6",1990,1990,"","alternative","study or report",null,"Dedicated Francisco Reservoir pressure zone · alternative: Creation of dedicated Francisco Reservoir pressure zone with a raised reservoir","unverified","C124904960",185,"https://archive.org/details/C124904960/page/n184",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:187/2",1990,1990,"","measure","study or report",null,"Francisco Reservoir system check valve · other: Check valve installed to prevent back-flow towards University Mound","unverified","C124904960",187,"https://archive.org/details/C124904960/page/n186","Francisco Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:187/4",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: Water surface stabilizes at about 145 feet; draws down to about 138 feet at lowest level","unverified","C124904960",187,"https://archive.org/details/C124904960/page/n186",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:187/5",1990,1990,"","finding","study or report",null,"Francisco Reservoir expanded floor area · other: With floor area expanded about 45 feet toward toe of hill, drawdown only to about 140 feet","unverified","C124904960",187,"https://archive.org/details/C124904960/page/n186",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:189/1",1990,1990,"","measure","study or report",null,"Francisco Reservoir · other: Water surface fluctuation graph, 145 ft Francisco Reservoir serving Marina District under ultimate maximum day demand","unverified","C124904960",189,"https://archive.org/details/C124904960/page/n188",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:191/1",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: Eliminates Marina District low pressure problems if raised to 145 ft elevation","unverified","C124904960",191,"https://archive.org/details/C124904960/page/n190",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:191/2",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: Nearly all of Marina area has very low pressures at peak hour with existing system","unverified","C124904960",191,"https://archive.org/details/C124904960/page/n190",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:191/3",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: Most Marina pressures raised above 30 psi with Francisco Reservoir","unverified","C124904960",191,"https://archive.org/details/C124904960/page/n190",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:191/8",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: Fire flow pressures still below required 20 psi minimum residual with Francisco Reservoir","unverified","C124904960",191,"https://archive.org/details/C124904960/page/n190",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:197/7",1990,1990,"","measure","study or report",null,"Connection line to Francisco Reservoir · other: 800 feet of 24-inch pipe connecting University Mound zone to Francisco Reservoir","unverified","C124904960",197,"https://archive.org/details/C124904960/page/n196","Bay Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","m",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:197/8",1990,1990,"","measure","study or report",null,"Francisco Reservoir direct attachment pipe · other: 800 feet of 24-inch pipe attaching reservoir to valved-off zone","unverified","C124904960",197,"https://archive.org/details/C124904960/page/n196",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:197/9",1990,1990,"","event","study or report",null,"Francisco Reservoir pressure zone modifications · cost usd: total about $755,000","unverified","C124904960",197,"https://archive.org/details/C124904960/page/n196",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:199/8",1990,1990,"","project","study or report",null,"Francisco Reservoir · other: raised to about elevation 145 feet","unverified","C124904960",199,"https://archive.org/details/C124904960/page/n198",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:199/9",1990,1990,"","project","study or report",null,"Francisco Reservoir · other: 5.8 million gallon reservoir","unverified","C124904960",199,"https://archive.org/details/C124904960/page/n198",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:211/2",1990,1990,"","finding","study or report",null,"Francisco Reservoir · alternative: Sunset supplies northern University Mound service area through Francisco Reservoir","unverified","C124904960",211,"https://archive.org/details/C124904960/page/n210",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,-3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:225/4",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: 2.5 MG storage, overflow elevation 135 feet, on Russian Hill","unverified","C124904960",225,"https://archive.org/details/C124904960/page/n224",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:227/1",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · recommendation: Reconstruction of Francisco Reservoir with 5.8 MG storage and reservoir overflow at elevation 145 feet","unverified","C124904960",227,"https://archive.org/details/C124904960/page/n226",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:227/3",1990,1990,"","finding","study or report",null,"Francisco Reservoir pressure zone · finding: Addition of Francisco Reservoir at elevation 145 feet would eliminate low pressure in Marina District except under fire fighting demands","unverified","C124904960",227,"https://archive.org/details/C124904960/page/n226",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:227/4",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: Some pressure would remain below the required minimum residual pressure during fire fighting demand","unverified","C124904960",227,"https://archive.org/details/C124904960/page/n226",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:227/5",1990,1990,"","finding","study or report",null,"Francisco Reservoir pressure zone · other: Ultimate maximum day water demand served by separate Francisco pressure zone, supplying only the Marina District","unverified","C124904960",227,"https://archive.org/details/C124904960/page/n226",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:227/6",1990,1990,"","action","study or report",null,"Francisco Reservoir · other: Check valves installed to allow gravity refilling from University Mound zone during low demand periods","unverified","C124904960",227,"https://archive.org/details/C124904960/page/n226",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:229/10",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · other: if geotechnically sound, berms raised ten to fifteen feet","unverified","C124904960",229,"https://archive.org/details/C124904960/page/n228",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:229/11",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · other: brick lining replaced by concrete slab; deck, roofing, columns and foundation replaced with concrete structural system","unverified","C124904960",229,"https://archive.org/details/C124904960/page/n228",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:229/3",1990,1990,"","project","study or report",null,"Francisco Reservoir · height ft: raise to an overflow elevation of 145 feet","unverified","C124904960",229,"https://archive.org/details/C124904960/page/n228",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:229/4",1990,1990,"","alternative","study or report",null,"Francisco Reservoir raising · other: about 5.8 million gallons of storage using the existing footprint","unverified","C124904960",229,"https://archive.org/details/C124904960/page/n228",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:229/5",1990,1990,"","finding","study or report",null,"Francisco Reservoir raising · other: additional 2.1 days of storage for the Marina District","unverified","C124904960",229,"https://archive.org/details/C124904960/page/n228",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:229/6",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: 3.5 MG would remain in storage at greatest drawdown from maximum day demand","unverified","C124904960",229,"https://archive.org/details/C124904960/page/n228",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:229/7",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: about 2.9 MG required for fire fighting reserve","unverified","C124904960",229,"https://archive.org/details/C124904960/page/n228",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:229/8",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: average 2.6-day residence time preventing stagnation","unverified","C124904960",229,"https://archive.org/details/C124904960/page/n228",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:229/9",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: insufficient geotechnical data for a definitive analysis","unverified","C124904960",229,"https://archive.org/details/C124904960/page/n228",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:23/6",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: located in northeast portion of the City, pressure zone reservoir 40","unverified","C124904960",23,"https://archive.org/details/C124904960/page/n22",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:233/3",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: no site-specific geotechnical information was available at the time of the study","unverified","C124904960",233,"https://archive.org/details/C124904960/page/n232",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:233/4",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · recommendation: additional geotechnical study including field exploration and laboratory testing","unverified","C124904960",233,"https://archive.org/details/C124904960/page/n232",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:233/5",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: dynamic model to determine elevation Francisco Reservoir could be refilled to after peak day demand","unverified","C124904960",233,"https://archive.org/details/C124904960/page/n232",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:27/2",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: assessed for integration into the City water distribution system",null,"C124904960",27,"https://archive.org/details/C124904960/page/n26",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,-4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:35/6",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: Area previously served by Francisco Reservoir is now part of the University Mound pressure zone","unverified","C124904960",35,"https://archive.org/details/C124904960/page/n34",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:41/10",1990,1990,"","finding","study or report",null,"Francisco Reservoir · finding: use discontinued because water could not cycle and would stagnate","unverified","C124904960",41,"https://archive.org/details/C124904960/page/n40","Hyde Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:41/5",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: total capacity 2.5 million gallons","unverified","C124904960",41,"https://archive.org/details/C124904960/page/n40","Hyde Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:41/6",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: overflow elevation 135 feet","unverified","C124904960",41,"https://archive.org/details/C124904960/page/n40","Hyde Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:41/7",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: located at Hyde and Francisco Streets, Russian Hill","unverified","C124904960",41,"https://archive.org/details/C124904960/page/n40","Hyde Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:63/3",1990,1990,"","recommendation","study or report",null,"Francisco Reservoir · recommendation: Fire Chief Blackburn would like to have Francisco Reservoir renovated to provide emergency fire supply for the Marina District","unverified","C124904960",63,"https://archive.org/details/C124904960/page/n62",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:85/6",1990,1990,"","site","study or report",null,"Francisco Reservoir · other: 5.8 MG reservoir would provide only four hours (0.2 days) of emergency supply","unverified","C124904960",85,"https://archive.org/details/C124904960/page/n84",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:85/8",1990,1990,"","alternative","study or report",null,"Francisco Reservoir · alternative: if plumbed to serve the Marina alone, Francisco Reservoir provides 2.1 days storage in addition to University Mound's 3.3 days","unverified","C124904960",85,"https://archive.org/details/C124904960/page/n84",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:95/5",1990,1990,"","project","study or report",null,"Francisco Reservoir · other: 5.8 MG reservoir serving new Marina District pressure zone","unverified","C124904960",95,"https://archive.org/details/C124904960/page/n94",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:95/6",1990,1990,"","finding","study or report",null,"Francisco Reservoir · other: 5.4 days of emergency storage to the Marina","unverified","C124904960",95,"https://archive.org/details/C124904960/page/n94",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:107/4",1990,1990,"1990","finding","study or report",null,"Francisco Reservoir · finding: would add 2.1 days of local storage to meet Marina District demands","unverified","C124904960",107,"https://archive.org/details/C124904960/page/n106",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:131/1",1990,1990,"1990","building","study or report",null,"Francisco Reservoir · other: existing reservoir impounded by a berm on a bench cut into north slope of Russian Hill","unverified","C124904960",131,"https://archive.org/details/C124904960/page/n130",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:135/1",1990,1990,"1990","finding","study or report",null,"Francisco Reservoir · finding: no known active faults at the site","unverified","C124904960",135,"https://archive.org/details/C124904960/page/n134",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:135/2",1990,1990,"1990","finding","study or report",null,"Francisco Reservoir · finding: Franciscan Formation bedrock encountered at 0 to 13 feet depth in vicinity of site","unverified","C124904960",135,"https://archive.org/details/C124904960/page/n134",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:135/3",1990,1990,"1990","finding","study or report",null,"Francisco Reservoir · finding: upper 10 to 20 feet of bedrock weathered and fractured","unverified","C124904960",135,"https://archive.org/details/C124904960/page/n134",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:135/4",1990,1990,"1990","action","study or report",null,"Francisco Reservoir · other: 10 to 30 feet of material removed to construct level bench for reservoir","unverified","C124904960",135,"https://archive.org/details/C124904960/page/n134",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:135/5",1990,1990,"1990","finding","study or report",null,"Francisco Reservoir · finding: no springs or seeps at base of cut south of reservoir, about 30 feet below original ground","unverified","C124904960",135,"https://archive.org/details/C124904960/page/n134",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:141/1",1990,1990,"1990","project","study or report",null,"Francisco Reservoir upgrade · cost usd: about $4.3 million (1990 dollars)","unverified","C124904960",141,"https://archive.org/details/C124904960/page/n140",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:141/2",1990,1990,"1990","measure","study or report",null,"Francisco Reservoir upgrade · other: Demolition and disposition of the existing structure","unverified","C124904960",141,"https://archive.org/details/C124904960/page/n140",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:141/3",1990,1990,"1990","measure","study or report",null,"Francisco Reservoir upgrade · other: Construction of a new roof structure and a new lining at the bottom","unverified","C124904960",141,"https://archive.org/details/C124904960/page/n140",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:141/4",1990,1990,"1990","measure","study or report",null,"Francisco Reservoir upgrade · other: New retaining walls at the south and east sides of the reservoir","unverified","C124904960",141,"https://archive.org/details/C124904960/page/n140",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:19/6",1990,1990,"1990","finding","study or report",null,"Francisco Reservoir · finding: Marina District, formerly served by Francisco Reservoir, is now part of the University Mound pressure zone","unverified","C124904960",19,"https://archive.org/details/C124904960/page/n18",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:209/6",1990,1990,"1990","finding","study or report",null,"Francisco Reservoir · other: Integration into University Mound System would reduce demand on University Mound by 2.2 mgd","unverified","C124904960",209,"https://archive.org/details/C124904960/page/n208",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:21/1",1990,1990,"1990","alternative","study or report",null,"Francisco Reservoir · alternative: raise rehabilitated reservoir ten feet to overflow elevation of 145 feet","unverified","C124904960",21,"https://archive.org/details/C124904960/page/n20",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:21/2",1990,1990,"1990","finding","study or report",null,"Francisco Reservoir · finding: raised reservoir would supply additional 2.6 days of local emergency storage for Marina District, total 5.4-day reserve","unverified","C124904960",21,"https://archive.org/details/C124904960/page/n20",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:21/3",1990,1990,"1990","finding","study or report",null,"Francisco Reservoir · finding: bedrock underlies reservoir at relatively shallow depth and appears adequate to support a raised reservoir","unverified","C124904960",21,"https://archive.org/details/C124904960/page/n20",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:21/4",1990,1990,"1990","measure","study or report",null,"Francisco Reservoir · other: replace brick lining with concrete slab, raise berms ten to fifteen feet, replace deck, roofing and columns","unverified","C124904960",21,"https://archive.org/details/C124904960/page/n20",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:21/5",1990,1990,"1990","measure","study or report",null,"Francisco Reservoir connection piping · other: approximately 1600 feet of piping and valving to connect reservoir into distribution network","unverified","C124904960",21,"https://archive.org/details/C124904960/page/n20",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:231/1",1990,1990,"1990","project","study or report",null,"Francisco Reservoir upgrade · cost usd: at least $4.3 million, exclusive of utility work, drainage, or other site improvement costs","unverified","C124904960",231,"https://archive.org/details/C124904960/page/n230",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:43/1",1990,1990,"1990","site","study or report",null,"Francisco Reservoir · other: expansion in width of up to 45 feet south of the existing reservoir to the base of the adjacent cut slope","unverified","C124904960",43,"https://archive.org/details/C124904960/page/n42",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:43/2",1990,1990,"1990","site","study or report",null,"Francisco Reservoir · height ft: increase in height of at least 30 feet is possible without obstructing views from nearby home owners","unverified","C124904960",43,"https://archive.org/details/C124904960/page/n42",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:280/1",1990,1990,"December 1989","site","study or report",null,"Francisco Reservoir · other: tied in at 138 feet (hydraulic model header; December 1989 analysis by Leedshill-Herkenhoff)","unverified","C124904960",280,"https://archive.org/details/C124904960/page/n279",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:21/7",1990,1990,"March 14, 1990","recommendation","study or report",null,"Francisco Reservoir · recommendation: rebuild to 5.8 million gallons with 145 ft overflow elevation serving new pressure zone for Marina District","unverified","C124904960",21,"https://archive.org/details/C124904960/page/n20",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:41/8",1990,1990,"about 30 years","finding","study or report",null,"Francisco Reservoir · finding: not being used, valved off from system for about 30 years","unverified","C124904960",41,"https://archive.org/details/C124904960/page/n40","Hyde Street",null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:175/18",1990,1990,"early 1970's","event","study or report",null,"Francisco Reservoir · other: disconnected from University Mound system","unverified","C124904960",175,"https://archive.org/details/C124904960/page/n174",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:23/5",1990,1990,"early 1970's","building","study or report",null,"Francisco Reservoir · other: isolated from the system; piping connections removed in early 1970s","unverified","C124904960",23,"https://archive.org/details/C124904960/page/n22",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:225/5",1990,1990,"early 1970s","event","study or report",null,"Francisco Reservoir · event: disconnected from University Mound pressure zone system","unverified","C124904960",225,"https://archive.org/details/C124904960/page/n224",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,4.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:13/7",1990,1990,"early 1970’s","building","study or report",null,"Francisco Reservoir · other: Disconnected from the distribution system","unverified","C124904960",13,"https://archive.org/details/C124904960/page/n12",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["d","qipu:sf/decision/meetingminutesb2008sanf_2:292/2",2008,2008,null,"resolution","water-sewers","referred","Proposed resolution urges the Public Utilities Commission to keep Francisco Reservoir as public recreation and open space; sent to committee.","quoted","meetingminutesb2008sanf_2",292,"https://archive.org/details/meetingminutesb2008sanf_2/page/n291",null,null,null,null,"n","a",0,4.0],["d","qipu:sf/decision/meetingminutesb2008sanf_2:293/2",2008,2008,null,"resolution","water-sewers","referred","Resolution urging the Public Utilities Commission to keep the Francisco Reservoir as public recreation and open space was referred to committee.","unverified","meetingminutesb2008sanf_2",293,"https://archive.org/details/meetingminutesb2008sanf_2/page/n292",null,null,null,null,"n","a",0,1.5],["d","qipu:sf/decision/meetingminutesb2008sanf_2:616/1",2008,2008,null,"resolution","water-sewers","passed","Board adopts policy urging the Public Utilities Commission to keep Francisco Reservoir as public recreation and open space.","quoted","meetingminutesb2008sanf_2",616,"https://archive.org/details/meetingminutesb2008sanf_2/page/n615",null,null,null,null,"n","a",0,9.49],["d","qipu:sf/decision/meetingminutesd2008sanf_0:427/2",2008,2008,"2008-12-16","resolution","parks","passed","Policy adopted urging the Public Utilities Commission to keep Francisco Reservoir as public recreation and open space.","quoted","meetingminutesd2008sanf_0",427,"https://archive.org/details/meetingminutesd2008sanf_0/page/n426",null,null,null,null,"n","a",0,9.41],["d","qipu:sf/decision/meetingminutesb2010sanf_0|g179",2010,2010,"2010-04-27",null,"budget","passed","Ten-year city building plan adopted; city to explore keeping Francisco Reservoir open.","unverified","meetingminutesb2010sanf_0",85,"https://archive.org/details/meetingminutesb2010sanf_0/page/n84",null,null,null,null,"n","a",0,5.87],["d","qipu:sf/decision/meetingminutesb2010sanf_0|g180",2010,2010,"2010-04-27",null,"budget","passed","Ten-year city building plan adopted; city to explore keeping Francisco Reservoir open.","unverified","meetingminutesb2010sanf_0",85,"https://archive.org/details/meetingminutesb2010sanf_0/page/n84",null,null,null,null,"n","a",0,5.87],["d","qipu:sf/decision/meetingminutesbo2014sanf|g825",2014,2014,"2014-07-22",null,"property","passed","Francisco Reservoir land moves to park department for $9.9M (≈ $14.1 million in 2026 dollars)","unverified","meetingminutesbo2014sanf",211,"https://archive.org/details/meetingminutesbo2014sanf/page/n210",null,null,null,null,"n","a",0,5.96],["d","qipu:sf/decision/meetingminutesbo2014sanf|g826",2014,2014,"2014-07-22",null,"property","passed","Francisco Reservoir land moves to park department for $9.9M (≈ $14.1 million in 2026 dollars).","unverified","meetingminutesbo2014sanf",211,"https://archive.org/details/meetingminutesbo2014sanf/page/n210",null,null,null,null,"n","a",0,5.96],["d","qipu:sf/decision/hand:francisco-reservoir-to-rec-park-2014",2014,2014,"2014-07-31","other",null,null,"Old Francisco Reservoir handed to Rec and Park to become a park","unverified",null,null,"https://sfgov.legistar.com/LegislationDetail.aspx?ID=28369&GUID=8BD06C8B-038F-44EA-A735-D51D17F6DB86","851 Bay St",null,"hand",null,"n","a",0,3.0],["d","qipu:sf/decision/meetingminutesbo2014sanf:154/4",2014,2014,"2014-11-04","resolution","parks","referred","Farrell proposes transferring Francisco Reservoir from SFPUC to Recreation and Park for $9,900,000 (≈ $14.1 million in 2026 dollars); sent to Land Use Committee.","quoted","meetingminutesbo2014sanf",154,"https://archive.org/details/meetingminutesbo2014sanf/page/n153",null,null,null,null,"n","a",0,4.0],["d","qipu:sf/decision/meetingminutesbo2014sanf|g603",2014,2014,"2014-11-04",null,"property","pending","Francisco Reservoir land moves to parks department; in committee.","unverified","meetingminutesbo2014sanf",154,"https://archive.org/details/meetingminutesbo2014sanf/page/n153",null,null,null,null,"n","a",0,3.0],["d","qipu:sf/decision/sfbos:bag071216|101",2016,2016,"2016-07-12","ordinance","city-services",null,"$25M (≈ $35.1 million in 2026 dollars) park deal with the Francisco Park Conservancy passes first reading","unverified",null,null,"https://sfbos.org/sites/default/files/bag071216_minutes.pdf#page=16",null,null,null,null,"n","m",0,-1.0],["d","qipu:sf/decision/sfbos:bag071916|5",2016,2016,"2016-07-19","ordinance","city-services",null,"$25M (≈ $35.1 million in 2026 dollars) gift of park building work from the Francisco Park Conservancy","unverified",null,null,"https://sfbos.org/sites/default/files/bag071916_minutes.pdf#page=3",null,null,null,null,"n","m",0,-1.0],["d","qipu:sf/decision/sfbos:bag071916|6",2016,2016,"2016-07-19","ordinance","running-the-city","passed","$25 million (≈ $35.1 million in 2026 dollars) gift accepted for new Francisco Reservoir park","unverified",null,null,"https://sfbos.org/sites/default/files/bag071916_minutes.pdf#page=3",null,null,null,null,"n","a",0,6.22],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:91/1",1990,2035,"2035","measure","study or report",null,"Francisco Reservoir · proposes: Use of Francisco Reservoir to increase Marina District Emergency Supply","unverified","C124904960",91,"https://archive.org/details/C124904960/page/n90",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0],["f","dl-sf-facts-v1.1-haiku55-2026-10/C124904960:91/3",1990,2035,"2035","site","study or report",null,"Francisco Reservoir · other: 5.8 MG Francisco Reservoir storage","unverified","C124904960",91,"https://archive.org/details/C124904960/page/n90",null,null,null,"Final report Balboa and Francisco Reservoirs needs assessment","n","a",0,3.0]]}