Cover of the report
City report · environmental impact report · 1998

City College of San Francisco Chinatown/North Beach campus (1998)

City College of San Francisco Chinatown/North Beach campus : draft environmental impact report

A draft environmental impact report on a proposed City College campus in Chinatown and North Beach, covering building plans, demolitions, parking and alternatives. Scan on the Internet Archive ↗

Facility
158,000 gsf facilityScan 56 ↗
Site area
about 22,400 square feetScan 51 ↗
Residential units
loss of 21 residential unitsScan 129 ↗
Parking
114 parking spacesScan 100 ↗
Report recommendations
  • The EIR assumes the St. Mary's project would be built on Lots 11 and 13 of the project block.Scan 99 ↗
  • The District would replace the existing structures and vacant Lot 5 with a 158,000 gsf facility.Scan 56 ↗
Findings
  • The EIR concludes the proposed project would not create significant transportation or traffic impacts.Scan 99 ↗
25 quotes from the scan

Printed words Quoted from the page as read from the scan.

Report recommendations-4e6b6ef80d11

“Alternative C would retain the Colombo Building, and would add one floor to the Colombo Building, covering 75% of the building footprint.”

Scan 23

Report recommendations-ceebe1461639

“The height of the new building at Lot 5 would be approximately 109 feet, and at Lot 12, the height would be approximately 94 feet.”

Scan 23

Findings-ea0619c3eedb

“The primary objective of Alternative C would be the preservation of the Colombo Building, which is eligible for listing in the National Register of Historic Places.”

Also on scan 129

Scan 23

Report recommendations-a34259c9da7e

“The proposed project includes the District's acquisition and potential development of Lots 4, 5, and 12.”

Scan 44

Backgrounds-b135dae24978

“Government Code sections 53091, and 53094 permits school districts to exempt themselves from local building and zoning codes for development of classroom facilities.”

Scan 47

Report recommendations-38117c0779b6

“There would no longer be 50 permanent residents at the site.”

Scan 56

Findings-63d902460e07

“The three-story Fong Building currently contains a ground-floor sewing shop, a real estate office, and 21 residential units in the upper stories.”

Scan 56

Findings-64d36c7a50e4

“The Colombo Building contains about 11,600 square feet of retail and office space in two stories.”

Scan 56

Report recommendations-c2c064ed7789

“As part of the project, two buildings, the Colombo Building and the Fong Building, would be demolished.”

Scan 56

Findings-56fb96c5672d

“The Fong Building is designated as “compatible” in the Chinatown Area Plan, which means it contributes to the historical character of Chinatown.”

Scan 78

Findings-7e8911e0da25

“That building has been determined not to be eligible for the National Register.”

Scan 78

Backgrounds-a7a35dfb7135

“The Chinatown Historic District has been proposed for listing in the National Register of Historic Places, and the Jackson Square Historic District is listed in the National Register.”

Scan 78

Findings-f572afd9547a

“Thus, the demolition of the Fong Building would not cause the loss of an individually historically or architecturally significant structure, and this would not be considered a significant environmental effect.”

Scan 78

Findings-1a5e08a9ed12

“Based on the transportation study, all study crosswalks currently operate at LOS B or better conditions, which indicates that pedestrians are generally crossing under free flow conditions.”

Scan 86

Findings-f38e76cff15e

“The estimated parking occupancy rate for the entire parking study area was approximately 91% during the weekday midday period.”

Scan 86

Findings-9a783996e9aa

“Therefore, cumulative parking impacts from development on the project block would be less than significant.”

Scan 99

Findings-f2d64d0969ce

“The proposed project would not create significant transportation or traffic impacts as discussed above for each impact topic.”

Scan 99

Report recommendations-cc10eac8770f

“As the project proposes 114 spaces, it would exceed Planning Code requirements.”

Scan 100

Findings-4c2078e00f77

“The project area is in a liquefaction hazard zone, as designated on the Seismic Hazard Zones Map, which covers most of San Francisco.”

Scan 104

Report recommendations-a8502a541d1e

“However, this alternative would provide 64 fewer parking spaces than the project.”

Scan 129

Findings-cdc14c8f2284

“In 1996, the District contracted with a real estate broker to assist in identifying suitable locations for a new campus.”

Scan 129

Findings-48f480c770b6

“For these reasons, the proposed project would have a less-than-significant growth-inducing effect.”

Scan 137

Backgrounds-62bc2809ff46

“The project site is located in a Seismic Hazard Zone because of potential liquefaction hazards, according to the official map prepared by the California Division of Mines and Geology.”

Scan 175

Findings-2bc5aee89d47

“Wastewater from the proposed project would be discharged to the City and County of San Francisco combined sewer system.”

Scan 177

Identifier ia:C101697812