Qipudata
San Francisco · v0.9.2

Records › City reports › The downtown plan (1983)

Cover of the report
City report · plan · 1983

The downtown plan (1983)

The downtown plan : proposal for citizen review

A proposal by the City Planning Department for citizen review of San Francisco's first comprehensive downtown policy revision in 17 years, covering height, streetwalls, open space, transport and zoning. Scan on the Internet Archive ↗

Office space
as much as another 24 million square feetScan 27 ↗
Hotel rooms
3,000 to 3,500 rooms by the year 2000Scan 38 ↗
Downtown office workers
Over 220,000 office workersScan 27 ↗
Parking spaces needed
Up to 22,000 parking spacesScan 147 ↗
Report recommendations
  • The Plan is the first proposal for comprehensive revision of downtown city policies and regulations in 17 years.Scan 2 ↗
  • The Downtown Plan does not recommend expanding street and bridge capacity to accommodate more cars entering downtown at peak.Scan 147 ↗
  • The document proposes removing the elevated Embarcadero Freeway between Howard and Broadway.Scan 156 ↗
31 quotes from the scan

Printed words Quoted from the page as read from the scan.

Report recommendations-b3f5a3d7be20

“The Plan represents the first proposal for comprehensive revision of city policies and regulations for downtown development in 17 years.”

Scan 2

Report recommendations-f620ad9aa874

“By the end of the century as much as another 24 million square feet could be added in the C-3 district.”

Scan 27

Findings-fd8485220384

“Over 220,000 office workers are employed in a wide range of managerial, professional, clerical, and less skilled occupations.”

Scan 27

Report recommendations-c196ef12e0db

“Guide the location of new hotels to minimize their adverse impacts on circulation, existing uses, and scale of development.”

Scan 38

Findings-0a315f6514da

“Current development in YBC includes about 4 million square feet of office, convention and other related facilities.”

Scan 48

Report recommendations-4b31e325bd57

“The Plan proposes to expand the C-3-O district southward to Folsom Street.”

Scan 48

Report recommendations-68194d707d6d

“The YBC redevelopment project should be deleted from the C-3 districts.”

Scan 48

Report recommendations-f954e13fd69d

“All of the existing C-3-S zone east of YBC bounded approximately by Natoma on the north, Folsom on the south, and the Embarcadero on the east is proposed to be reclassified as a special development district.”

Scan 48

Report recommendations-f71bfc97e198

“These areas are publicly owned and are in public use. They should be rezoned to P (Public).”

Scan 50

Report recommendations-0759b5f1fe68

“The base FAR in the C-3-G is proposed to be set at 8:1.”

Scan 58

Findings-aa2e5af39ab4

“The overall density of current development in the C-3-G district, excluding Chinatown, is 4.6:1.”

Scan 58

Report recommendations-03294867a1db

“Develop an open space system that gives every person living and working downtown access to a sizable sunlit open space within convenient walking distance.”

Scan 82

Findings-6d6e99bb0ed9

“The average distance most people are willing to walk to a park or plaza is approximately 900 feet.”

Scan 82

Findings-bdee33b50682

“Plazas and parks more than three feet above or below grade are less inviting, and as a result, are less frequently used.”

Scan 82

Report recommendations-ddb561e2f7ba

“The landmark designation process set out in Article 10 of the City Planning Code would not be changed by the proposals in this Plan.”

Scan 100

Findings-e8a812c047dd

“Most of the significant buildings are likely to be eligible for listing in the National Register of Historic Places.”

Scan 105

Report recommendations-27a58ede1462

“To provide more flexibility in building design and height, and to encourage slenderer and more sculptured tops for tall structures, two optional upper tower extensions are proposed.”

Scan 123

Report recommendations-410f52525895

“Create sun access criteria for parks, plazas, Squares, and lunchtime malls.”

Scan 134

Report recommendations-af26b6c1a973

“The height to be allowed in the areas shown on the map would be established in the context of a specific development proposal through the design review process.”

Scan 134

Report recommendations-0b34c595d811

“Structures generally should be built to the street property line along the entire frontage to a sufficient height for proper definition of street space.”

Scan 137

Report recommendations-9e296a47badb

“Provide setbacks above a building base to maintain the continuity of the predominant streetwalls along the street.”

Scan 137

Report recommendations-3d8f12b363db

“To accommodate the additional vehicles, freeway-bridge capacity would have to be expanded about 20%.”

Scan 146

Report recommendations-6bfbae498e12

“Most transit carriers would be able to accommodate the projected demand with their 1987 planned capacity.”

Scan 146

Report recommendations-0b7e78645d1b

“The Plan, therefore, contemplates another Strategy with two principal efforts.”

Scan 147

Report recommendations-91fb0f9764d7

“Up to 22,000 parking spaces would be required to handle the increased number of vehicles, assuming the freeways and bridges could carry them.”

Scan 147

Report recommendations-bff09b3e4a4b

“For this reason, the Downtown Plan does not recommend expanding the capacity of streets and bridges to accommodate an increase in the number of cars entering the general downtown area during the peak period.”

Scan 147

Report recommendations-0719ff7651f4

“POLICY Do not increase (and where possible reduce) the existing automobile Capacity of the bridges, highways and freeways entering the city.”

Scan 156

Report recommendations-696cc55946a9

“The elevated portion between Howard and Broadway should be removed and replaced by on- and off-ramps connecting to the Embarcadero surface roadway near Howard and Folsom.”

Scan 156

Report recommendations-d596e6a18bda

“The stub end of I-280 should be removed as far as 6th Street and replaced as surface streets connected to the reconstructed Embarcadero Roadway.”

Scan 156

Report recommendations-cfa307ca2312

“The existing loading requirements in the Planning Code are inadequate and should be revised as shown on Table 23.”

Scan 166

Identifier ia:c124897620