| 1990 | Golden Gate Bridge main suspension bridge · other: -6450-foot long suspension bridge, vulnerable to damage in [name withheld] 8+ earthquake | building | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge main suspension bridge · recommendation: strengthen reinforced concrete piers and lower tower sections, restrain tower-pier connections | recommendation | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge main suspension bridge · other: center span 4200 ft; two side spans 1125 ft each | building | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge main suspension bridge · other: 3D global model developed from the South (San Francisco) anchorage to the North (Marin) anchorage | building | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge main suspension bridge · other: 9,933 frame elements connecting 4,775 nodes in original model | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge main suspension bridge · other: Total active degrees of freedom in final model in the order of 4000 | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge main suspension bridge · recommendation: requires strengthening of its reinforced concrete piers and lower tower sections | recommendation | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge main suspension cables · other: two 36.5 in. diameter steel wire cables spaced 90 ft apart | building | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |