Qipudata
San Francisco · v0.7.1
qipu data›San Francisco›Places›Golden Gate Bridge main tower

Golden Gate Bridge main tower

Named in the records1990

24 records of San Francisco tie this place, 1990: 0 decisions of the Board of Supervisors and 24 facts read from city reports. Open the full list, with filters for years, kind and outcome.

Kind
Named in the records
Records
24: 0 Board decisions, 24 facts from city reports
Years
1990

What the records say

All 24 records, in date order. The one-line summaries were written by a language model from the printed page; open the page to check the wording.

WhenWhat the record saysOutcomeSource
1990Golden Gate Bridge · finding: Maximum additional cable force induced by vertical earthquake excitation near the main tower: 10,539 kipbuildingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower base · finding: rotational ductility demand about 2.2 at upper level earthquake (475-year return period)findingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower shaft · finding: local buckling and tensile yielding in web plate under maximum credible earthquakefindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · finding: stress conditions in parts of the main tower exceed yield or buckling limits (Baron study)findingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge tower end-restraint · finding: tower end-restraint assumed by Baron cannot possibly be attainedfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower shaft · other: 96 hold-down steel angles riveted to tower shaft web platesbuildingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower shaft · other: 78 steel dowels providing positive shear connectionbuildingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower base connection · other: 96 hold down steel angles riveted to the web plates of the tower shaftbuildingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower base connection · other: 78 steel dowels providing positive shear connectionbuildingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower shaft · other: hold-down angles pre-stretched to 105 kip before rivetingbuildingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · finding: Computed and measured tower periods correlate very closely, validating the computer modelfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower model · finding: computed and measured tower periods closely correlate, validating the computer modelfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · other: Modal damping ratio 1.3% for first longitudinal tower mode (T = 1.332 sec.)measureCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · other: Modal damping ratio 2.2% for first transverse tower mode (T = 2.1845 sec.)measureCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · other: Modal damping ratio 1.3% for first torsional tower mode (T = 1.2136 sec.)measureCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · other: Damping ratios up to 5% for longer period modes (T = 5 sec.) involving tower and suspended structurefindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · other: Modal damping ratio of 3% expected in the period range of 1 to 2 secondsrecommendationCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · finding: Uplifting of the base plate occurred initially at the west edge of the west shaft when 52% of the displacement amplitude was imposedfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · finding: First hold-down rivet connection shear failure occurred when 78% of the displacement amplitude was imposedfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · finding: Two-thirds of the rivet connections in the west shaft failed in shear and 30 of the 42 filaments upliftedfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · finding: The maximum compressive stress in the east shaft was 20.3 ksifindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · finding: maximum compressive stress at the base of the east shaft was 17.2 ksifindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower base · finding: about half of base section under each shaft uplifted under rocking responsefindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge main tower · finding: massive concrete pier and rock foundation have practically no effect on tower responsefindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗

All 24 records, with filters · this place's data as JSON · release v0.7.1 · CC0 1.0