| 1990 | Golden Gate Bridge pylons and anchorage housings · finding: reinforced concrete; damage similar to approach viaducts in [name withheld] 8+ earthquake | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · other: monolithic reinforced concrete panel and frame construction | building | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · other: south pylons support end of 1125 ft side span and end of 320 ft arch span | building | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · other: north pylons support 1125 ft suspension span | building | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · height ft: up to 250 ft high | measure | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · finding: Base shear demands one to six times greater than nominal capacities | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · finding: Base moment demands significantly greater than tension capacities of foundations | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · finding: cable tie-downs in the pylons quite vulnerable; damage could cause secondary damage | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge tie-downs · other: total calculated stress not greater than 4 Fy (printed as '4 Fy) | measure | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons and anchorage housings · finding: Reinforced concrete pylons and anchorage housings would experience damage similar to the approach viaducts | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · finding: cable tie-downs quite vulnerable; damage could cause secondary damage | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · finding: Demand/Capacity ratio 3.6 using f'c of 6,000 psi; possible concrete shear failure | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · finding: Possibility of concrete shear failure when ground acceleration reached 0.20g | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · recommendation: Urgent need to strengthen the pylons | recommendation | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge cable tie-downs · finding: Failure of the pylons may particularly endanger the cable tie-down and the main suspension span | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |
| 1990 | Golden Gate Bridge pylons · finding: Pylons need retrofitting anyway | finding | City report: Golden Gate Bridge seismic evaluation scanned page ↗ |