Qipudata
San Francisco · v0.7.1
qipu data›San Francisco›Places›Golden Gate Bridge pylons

Golden Gate Bridge pylons

Named in the records1990

16 records of San Francisco tie this place, 1990: 0 decisions of the Board of Supervisors and 16 facts read from city reports. Open the full list, with filters for years, kind and outcome.

Kind
Named in the records
Records
16: 0 Board decisions, 16 facts from city reports
Years
1990

What the records say

All 16 records, in date order. The one-line summaries were written by a language model from the printed page; open the page to check the wording.

WhenWhat the record saysOutcomeSource
1990Golden Gate Bridge pylons and anchorage housings · finding: reinforced concrete; damage similar to approach viaducts in [name withheld] 8+ earthquakefindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · other: monolithic reinforced concrete panel and frame constructionbuildingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · other: south pylons support end of 1125 ft side span and end of 320 ft arch spanbuildingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · other: north pylons support 1125 ft suspension spanbuildingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · height ft: up to 250 ft highmeasureCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · finding: Base shear demands one to six times greater than nominal capacitiesfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · finding: Base moment demands significantly greater than tension capacities of foundationsfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · finding: cable tie-downs in the pylons quite vulnerable; damage could cause secondary damagefindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge tie-downs · other: total calculated stress not greater than 4 Fy (printed as '4 Fy)measureCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons and anchorage housings · finding: Reinforced concrete pylons and anchorage housings would experience damage similar to the approach viaductsfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · finding: cable tie-downs quite vulnerable; damage could cause secondary damagefindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · finding: Demand/Capacity ratio 3.6 using f'c of 6,000 psi; possible concrete shear failurefindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · finding: Possibility of concrete shear failure when ground acceleration reached 0.20gfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · recommendation: Urgent need to strengthen the pylonsrecommendationCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge cable tie-downs · finding: Failure of the pylons may particularly endanger the cable tie-down and the main suspension spanfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗
1990Golden Gate Bridge pylons · finding: Pylons need retrofitting anywayfindingCity report: Golden Gate Bridge seismic evaluation
scanned page ↗

All 16 records, with filters · this place's data as JSON · release v0.7.1 · CC0 1.0