Findings-29cd7dbed12a
“Earthquake and wind forces were considered as horizontal static effects although their actions are actually dynamic.”
Scan 20Records › City reports › Golden Gate Bridge seismic evaluation (1990)
Golden Gate Bridge seismic evaluation
A seismic evaluation by the Golden Gate Bridge, Highway and Transportation District, judging the bridge's earthquake resistance and recommending retrofits. Scan on the Internet Archive ↗
Printed words Quoted from the page as read from the scan.
Findings-29cd7dbed12a
“Earthquake and wind forces were considered as horizontal static effects although their actions are actually dynamic.”
Scan 20Findings-59d0dc32b2eb
“The result is a bridge which is quite flexible and which has a high reserve in vertical load capacity.”
Scan 20Findings-b1a1a2ffd0e0
“It was not until 1930 that the final length of the span was determined at 4200 ft and a cable spacing of 90 ft was selected.”
Scan 20Findings-8772c1a118db
“This replacement resulted in a net reduction in weight of the suspension bridge of about eleven thousand tons.”
Scan 24Findings-b748348c21f6
“The Golden Gate Bridge, Highway and Transportation District retrofitted the approaches of the Golden Gate Bridge using the Caltrans guidelines in 1982.”
Scan 24Findings-d3d225f9b904
“In keeping with the Caltrans policy at that time, no overall upgrade of the seismic resisting system was performed.”
Scan 24Findings-74f64f02381b
“The Holocene and historical slip rate of the San Andreas decreases northward from 32 mm/year near Bitterwater to about 12 mm/year along the San Francisco Peninsula.”
Scan 38Findings-c7fcb220ac18
“The faults most critical to the seismic risk at the Golden Gate Bridge are the San Andreas fault, the Hayward fault, and the Calaveras fault.”
Scan 38Report recommendations-bc93a85ee9c5
“The lane closure or lane load reductions should not last more than two weeks.”
Scan 51Report recommendations-c87a8a08522f
“In any of the above cases, the bridge should not be closed for more than one day.”
Scan 51
Scan 65Findings-a5ec196e8333
“The yield moments corresponding to initial rivet shear failure are Mzy = 900,000 Kip-ft.”
Scan 65Findings-e7f15bb36c5e
“The first mode is the transverse vibration of the main span deck with a natural period of 20.56 sec.”
Scan 65Findings-2ed34cca60ab
“Very close correlation between computed and measured values were obtained that essentially validated the computer model developed.”
Scan 66Findings-0571e6990a74
“The maximum longitudinal displacement of the main span was 2.3 ft, which is about 53% higher than the one-way movement of 18 in. provided by the expansion joints.”
Scan 74Findings-6659c93d03fd
“The maximum longitudinal displacement of the side spans was 3.2 ft on the San Francisco side and 3.75 ft on the Marin side.”
Scan 74
Scan 74Findings-c2bb962aa8a5
“At center of the main span, the deck experienced lateral displacement of 11.76 ft and vertical displacement of 6.76 ft which are not unusual.”
Scan 74Findings-2a20bd5379b3
“The longitudinal response of the north tower was much higher than that of the south tower while the transverse responses in both towers were practically the same.”
Scan 87Findings-e0ad3f7c00ec
“For side span cable, the equivalent stiffness was 15,700 kip/ft; for main span cable, 5200 kip/ft.”
Scan 87Findings-80ec76b69fb9
“About 80% of the longitudinal inertia force developed in the side span deck will be delivered to the tower through a hinge connection.”
Scan 96Findings-57963c699aae
“The overall dynamics (i.e. frequencies and mode shapes) and the seismic behavior of the structural system, however, are adequately captured using the simpler truss idealization.”
Scan 102Backgrounds-8759e14f6bea
“Restrainers were installed across the bearings of the approach structures in a seismic upgrade performed in 1982.”
Scan 102Findings-84f4af1d859b
“Members not in compliance with the design criteria and therefore in need of seismic upgrade are illustrated in Fig. 6.11.”
Scan 112Findings-5b46f9f61963
“The most critical components for retrofit are the foundations, supporting frames, structural bearings supporting the trusses, and the expansion joint restrainers.”
Scan 122Report recommendations-882cd8d1ef18
“Structural fuses may not have any application to the Golden Gate Bridge but the lock-up devices may warrant further consideration.”
Scan 128Findings-e2419fef57ec
“The pylons need retrofitting anyway and with a little additional reinforcement, the pylons may be able to take the increase in loading.”
Scan 128Backgrounds-1b7155b7cb8d
“This seismic evaluation was commissioned by the Board of Directors of the Golden Gate Bridge, Highway & Transportation District in November and December 1989.”
Scan 134Identifier ia:C123303273