Proposed installation of rapid transit trains on Golden Gate Bridge (1962)

Report on proposed installation of rapid transit trains on Golden Gate Bridge

A study by the Golden Gate Bridge, Highway and Transportation District on whether rapid transit trains could be added to the bridge, and what it would cost structurally. Scan on the Internet Archive ↗

Dead load
25,700 lbs. per ft. center spanScan 12 ↗
Center span dead load
22,900 lbs. per ft.Scan 10 ↗
Sidewalk width
10 ft. to 6 ft.Scan 10 ↗

“[name withheld]” stands for a name the release withholds (Privacy).

Report recommendations
  • The report considers installation of rapid transit on the bridge inadvisable because the cables would be overstressed.Scan 18 ↗
Findings
  • The report calculates the axial cable stress under rapid transit operation at 97,750 psi, about 12,000 psi above its conservative limit.Scan 18 ↗
  • The board concludes that installing rapid transit would decrease the possible life of the bridge.Scan 8 ↗
Board decisions
  • Request to widen Golden Gate Bridge approaches grantedRecord · Journal page ↗
  • 1962 · This reportGolden Gate Bridge, Highway and Transportation District
31 quotes from the scan

Printed words Quoted from the page as read from the scan.

Report recommendations-95cce9b12319

“We do not recommend, however, the replacement of the present solid deck slabs by open steel grating in any of the roadway lanes or the sidewalks.”

Scan 7

Findings-95e7bf053c31

“As originally designed and built the Golden Gate Bridge had a certain reserve capacity to carry additional load.”

Scan 7

Report recommendations-d564c3c32a56

“For the moving load on the tracks we have assumed light-weight rapid transit trains as contemplated by the San Francisco Bay Area Rapid Transit District.”

Scan 7

Findings-1b4a9565b10a

“These additions increased the dead load of the center span to its present value of 22,900 lbs. per ft. of bridge.”

Scan 10

Report recommendations-b4efd82cd1b5

“It would be advisable to maintain a reserve for such possible future additional dead loads to the extent of at least 800 lbs. per ft. of bridge before additions of rapid transit facilities are made.”

Scan 10

Report recommendations-b7089f5aa0e9

“The total dead load of the center span with this modest reserve would amount to 23,700 lbs. per ft. of bridge.”

Scan 10

Report recommendations-93c70b37ac51

“It would not be advisable, however, to substitute open gratings for the present solid flooring in either the sidewalks or any of the roadway lanes.”

Scan 11

Report recommendations-aebd37a71391

“For new structural members to support the tracks (stringers, bracing between stringers, etc.) 535 Ibs.”

Scan 11

Report recommendations-2e7d7baeb062

“This restricted length live load of 3,200 + 2,800 = 6,000 Ibs. per ft. of bridge is placed in a position to cause maximum stress in the stiffening trusses.”

Scan 14

Report recommendations-b165ea633ef2

“In any case we consider it essential that adequate protective measures against such happenings, as well as against possible derailments, be taken.”

Scan 14

Report recommendations-f55a47662cb5

“The above highway and rapid transit live loads assumed for this study give a combined live load of 2,900 + 1,700 = 4,600 Ibs. per ft.”

Scan 14

Report recommendations-1b09fdbb1637

“Because of this overstressing of the existing cables we consider the installation of rapid transit inadvisable.”

Scan 18

Findings-b99698772249

“The calculated axial cable stress under rapid transit operation is 97,750 Ibs. per sq. in.”

Scan 18

Findings-301c4e150169

“We conclude that rapid transit installation would overstress the anchorage chains.”

Scan 19

Findings-5aa934e61afa

“Under rapid transit operation the calculated stress under the assumed loads will reach 30,300 Ibs. per sq. in.”

Scan 19

Findings-5b9320fc2850

“The permissible single-part stress, therefore, is somewhat exceeded.”

Scan 22

Report recommendations-10a60dee414b

“Mr. [name withheld] proposes to jack up the stiffening trusses and insert shims between the suspender sockets and their bearings.”

Scan 23

Findings-4c87b3718d63

“Under a combination of these loads and a temperature of 110° F. the deflection at the center of the center span from the original dead load position would be 19.3 ft.”

Scan 23

Findings-b727e35714a3

“This would cause an encroachment of up to about 9 ft. on the 220 ft. under-clearance originally required by the War Department.”

Scan 23

Findings-dd8e726106f8

“This or any other method would undoubtedly be feasible, but would involve very tedious, delicate and costly operations.”

Scan 23

Backgrounds-ddc15e7d0506

“A ruling with respect to such encroachment would have to be obtained from the present Department of the Army.”

Scan 23

Findings-63c280bf2969

“This would create a very narrow, deep tube and, although a few small handholes are provided, would not permit adequate inspection and maintenance.”

Scan 24

Findings-7454256e9ab9

“All these detailed design studies would likely divulge further necessary increases in the dead weight of the superstructure and, in turn, increase the already excessive calculated stresses in the major carrying members under rapid transit operation.”

Scan 24

Report recommendations-974995742b40

“Mr. [name withheld] proposes to reinforce the central part of the transverse struts which are to carry the rapid transit track stringers by replacing the latticing by solid web plates.”

Scan 24

Findings-bde7e36701eb

“Certain of these changes, such as the expansion dams of the highway deck, could not be accomplished without serious interference with the traffic.”

Scan 24

Findings-590999384316

“The conclusion is reached that the Golden Gate bridge is adequately safe from fatigue failures under present highway loadings.”

Scan 25

Findings-eb48ce8a5ad8

“This stress fluctuation capability is about three to four times as great as the estimated maximum range in stress for the eye-bars in the bridge; hence there should be no problem of fatigue in these members.”

Scan 27

Findings-b17a291297d4

“The fatigue resistance at 2,000,000 or more cycles of application of load corresponds to a stress fluctuation, in either complete reversal or in the range from zero-to-maximum tensile stress, of approximately 20,000 psi.”

Scan 28